A water efficiency calculation shows Building Control that a new home in England will use no more than 125 litres of water per person per day under Part G, or 110 litres where your planning permission says so. From £20 + VAT. Guide price. Get a free quote for your project.

Part G Compliance Water usage calculated for each dwelling
Planning Targets Support for standard and tighter limits
Design Advice Practical fixture changes where required
Nationwide Service Single plots and larger developments
Need It Today?

Do It Yourself Online in Minutes

Enter your toilets, taps, showers and appliances on our sister site, Water Calculations, and get your Part G water calculation without waiting for a quote. From £20 + VAT.

Start online, from £20 + VAT

Several Plots?

Building a few homes or a whole site? Water Calculations has pricing made for developers.

See development pricing →

Rather we handled it for you? Get a free quote.

What Are Water Efficiency Calculations?

Water efficiency calculations estimate the daily use of wholesome water within a new dwelling. The assessment considers the proposed sanitary fittings, appliances and water-saving measures to determine the expected consumption per person per day.

These calculations are commonly required for Building Regulations compliance and may also be needed to satisfy a planning condition, sustainability requirement or local water-efficiency target.

One Stop Consult coordinates assessors who can review the proposed fixture specification, complete the calculation and advise on practical changes where the initial design exceeds the required water-use limit.

Building Regulations

When Are Water Efficiency Calculations Required?

They are commonly requested for new homes and certain residential conversion projects.

New-Build Dwellings

New houses and flats normally require a calculation demonstrating that the proposed fittings satisfy the applicable water-use target.

Residential Conversions

A calculation may be required where existing buildings are converted into new self-contained dwellings.

Planning Conditions

Some planning permissions require a tighter water-consumption limit than the standard Building Regulations target.

Larger Housing Developments

Multi-unit schemes may require separate calculations for each dwelling type or specification.

Water Consumption Targets

Part G of the Building Regulations limits how much water a new home is designed to use. There are two figures to know.

125 litres per person per day is the standard limit for every new home in England, including flats and homes made by converting a building that was not a home before.
110 litres per person per day is the tighter optional requirement. It applies when your planning permission says so, which is common in water-stressed areas such as the South East and East of England.
Wales uses 110 litres as its standard limit for new-build homes and 125 litres for conversions. Tell us if your site is in Wales.

Check your planning decision notice. If any condition mentions water use, the 110 litre target probably applies.

The assessor models the selected fixtures and appliances to establish whether the proposed dwelling falls within the required limit.

Two Ways to Comply

Full Calculation or Fittings Approach?

Approved Document G gives two routes. You can run the full water efficiency calculation, or use the simpler fittings approach, where every fitting stays at or below a set maximum.

125 Litre Maximums

WC: 6/4 litres dual flush or 4.5 single
Shower: 10 l/min
Bath: 185 litres
Basin taps: 6 l/min
Sink taps: 8 l/min
Dishwasher: 1.25 l per place setting
Washing machine: 8.17 l per kg

110 Litre Maximums

WC: 4/2.6 litres dual flush
Shower: 8 l/min
Bath: 170 litres
Basin taps: 5 l/min
Sink taps: 6 l/min
Dishwasher: 1.25 l per place setting
Washing machine: 8.17 l per kg

When the Full Calculation Is Needed

If any fitting goes over these figures, the calculation has to be done. The same applies if there is no shower, or if you are fitting a waste disposal unit, a water softener or water re-use.

Telling Building Control

A notice with the result must go to Building Control, in most cases no later than five days after completion. They are unlikely to give the completion certificate without it.

These maximums come from Tables 2.1 and 2.2 of Approved Document G. Want a quick check first? Try the free Part G calculator on our Water Calculations website.

Worked Example

Worked Example: A Typical House at 125 and 110 Litres

This is how the Part G water efficiency calculator in Appendix A of Approved Document G works for a house with a bath, a shower, basin and kitchen taps, a washing machine and a dishwasher. Each fitting’s size or flow rate is multiplied by its use factor, and some fittings add a fixed amount.

FittingHouse at 125 litresHouse at 110 litres
WC, dual flush6/4 litres: 20.604/2.6 litres: 13.54
Basin taps6 l/min: 11.065 l/min: 9.48
Bath (shower also fitted)185 litres: 20.35170 litres: 18.70
Shower (bath also fitted)10 l/min: 43.708 l/min: 34.96
Kitchen sink taps8 l/min: 13.886 l/min: 13.00
Washing machine8.17 l/kg: 17.168.17 l/kg: 17.16
Dishwasher1.25 l/place setting: 4.501.25 l/place setting: 4.50
Total calculated use131.25111.34
× normalisation factor 0.91119.44101.32
+ outdoor use5.005.00
Total water use124.4 litres per person per day: meets 125106.3 litres per person per day: meets 110

How the Sums Work

The use factors come from Table A1 of Approved Document G. A dual-flush WC counts the full flush × 1.46 and the part flush × 2.96. Basin taps are the flow rate × 1.58, plus 1.58. A bath fitted alongside a shower is its capacity × 0.11, and the shower is its flow rate × 4.37. Kitchen sink taps are the flow rate × 0.44, plus 10.36. The washing machine is litres per kilogram × 2.1, and the dishwasher litres per place setting × 3.6.

The fittings here are the maximum figures in Tables 2.1 and 2.2 of Approved Document G. Your own fittings will give a different total, and one high-flow shower or large bath can push a home over the limit.

Is the Water Target Changing?

The government consulted from September to December 2025 on lowering the standard limit from 125 to 105 litres per person per day, and the optional limit from 110 to 100 litres.

No decision or start date has been published yet. Today’s limits still apply.

If your homes may be built after a change, tell us and we can check your fittings against the lower figure as well, so there are no surprises at completion.

Calculation Inputs

What Is Included in the Calculation?

The result is based on the flow rates, capacities and consumption details of the proposed water-using fittings.

Toilets

Flush volume, dual-flush performance and the number of WCs serving the dwelling.

Bathroom and Kitchen Taps

Flow rates for washbasin, kitchen and utility-room taps.

Showers

Shower flow rates, including standard, mixer and electric shower arrangements.

Baths

The internal capacity of each proposed bath within the dwelling.

Dishwashers

Water consumption per cycle where a dishwasher is provided or a defined specification is used.

Washing Machines

Water consumption per cycle for the proposed appliance or assumed fitting allowance.

Design Optimisation

How Can Water Consumption Be Reduced?

Where the proposed specification exceeds the required target, the fixtures can usually be adjusted without major redesign.

Lower-Flow Taps

Select taps or suitable flow regulators with reduced but practical flow rates.

Efficient Showers

Use shower fittings that provide suitable performance while limiting unnecessary water use.

Dual-Flush Toilets

Specify efficient dual-flush WCs with appropriate full and reduced flush volumes.

Smaller Bath Capacity

Select a bath with a lower measured capacity where this is compatible with the intended design.

Efficient Appliances

Use washing machines and dishwashers with lower water consumption per cycle.

Rainwater or Greywater Systems

Suitable reuse systems may contribute to the wider water strategy where they are properly designed and specified.

How the Water Calculation Process Works

The assessment can often be completed remotely using the proposed drawings and product information.

Confirm the project type and applicable water target.
Review the proposed dwelling layouts and fixture schedule.
Enter the flow rates, capacities and appliance data.
Complete the water-use calculation for each dwelling type.
Recommend specification changes where required.
Issue the final report for Building Control or planning.
1

Project Review

Establish the number of dwellings, project stage and target that must be achieved.

2

Fixture Review

Check the proposed toilets, taps, showers, baths and appliances.

3

Calculation

Calculate the estimated daily water use per person for the proposed dwelling.

4

Compliance Advice

Identify practical fixture changes where the initial result exceeds the required limit.

5

Final Report

Issue the completed calculation for submission to the relevant authority.

Information Required for a Quotation

Provide the full project address, number of dwellings, current project stage and the latest proposed floor plans.

Please also send the water-fixture schedule or product information for the toilets, taps, showers, baths, washing machines and dishwashers.

Avoid Delays

Common Water Calculation Issues

Clear and consistent product information helps avoid late design changes.

Unconfirmed Fixture Flow Rates

Generic or missing product information can lead to assumptions that produce a higher result.

Wrong Project Target

The calculation may need revising if a tighter planning requirement is discovered later.

Product Substitutions

Replacing specified taps, showers or toilets during construction can affect the final compliance result.

Mixed Specifications

Different dwelling types or bathroom layouts may require separate calculations rather than one generic assessment.

Project Types

Water Calculations for Residential Developments

Nationwide Water Efficiency Calculation Service

One Stop Consult coordinates water-efficiency calculations for residential projects throughout mainland UK. Support is available for individual homes, conversions, apartment schemes and larger housing developments.

We also have local pages for water calculations in Birmingham, Bristol, Coventry, Leeds, Leicester, Liverpool, London, Manchester, Nottingham and Sheffield.

Important Water Efficiency Information

The applicable water-consumption target depends on the Building Regulations, planning permission and any project-specific condition. The final result is based on the product information and flow rates supplied. Any changes to the sanitaryware or appliance specification may affect compliance and should be reviewed before installation. One Stop Consult provides consultancy and coordination support through its specialist assessor network.

Frequently Asked Questions

Water Efficiency Calculation FAQs

What is a water efficiency calculation?

It estimates the daily wholesome-water consumption of a dwelling using the proposed toilets, taps, showers, baths and appliances.

Do new homes need a water calculation?

New dwellings commonly require a calculation to demonstrate compliance with the applicable Building Regulations target.

Can planning require a tighter target?

Yes. Some planning permissions include an optional lower water-use requirement that must be demonstrated separately.

What information do you need?

We normally require the proposed plans and product details for the toilets, taps, showers, baths and relevant appliances.

Can the calculation be completed before products are chosen?

Yes, but provisional values or a suggested compliant specification may need to be used and confirmed later.

What happens if the design exceeds the target?

The specification can usually be adjusted by reducing selected flow rates, flush volumes or appliance consumption.

Do conversions need water calculations?

Yes, where the conversion makes a home out of a building that was not one before, such as a barn, office or shop turned into a house or flats. The Part G limit does not apply where a building that already contains homes is changed into a different number of homes, such as a house split into flats, although your planning permission may still have a water condition.

Do you provide Water Calculations nationwide?

Yes. We coordinate assessments for eligible residential projects throughout mainland UK.

What is the Part G water target?

125 litres per person per day for new homes in England, or 110 litres where your planning permission asks for it.

Is the water target changing?

The government has consulted on lowering it to 105 litres, but nothing has been decided yet. We can check your fittings against the lower figure as well if you would like.

How much does a water calculation cost?

From £20 + VAT. Guide price. Get a free quote for your project.

What is the fittings approach?

It is the simpler way to meet Part G. If every fitting stays within the maximum figures in Approved Document G, you do not need the full calculation. If any fitting goes over, you do.

When does the water calculation have to reach Building Control?

In most cases the notice must be given no later than five days after completion. Building Control is unlikely to give the completion certificate without it.

Is there a free Part G water calculator?

Yes. You can try your fittings in the free calculator on our sister site, Water Calculations. Building Control still needs a calculation based on the final specification, so send us your fittings schedule if you want us to prepare it.

Does an extension need a water calculation?

No. The Part G water limit applies to new homes, including most homes made by converting another building. An extension to an existing house does not need one, unless your planning permission has a condition that asks for it.

Will Building Control accept the water calculation?

Yes, if it follows the method in Approved Document G. Part G requires the water use to be worked out with the government’s approved method, the water efficiency calculator in Appendix A, or the fittings approach, and the result is sent to Building Control in a notice. Building Control decides whether the evidence is enough, so we set out the fittings and the figures clearly.

Do I need a design-stage and an as-built water calculation?

Most projects have both. A design-stage calculation, from the fittings schedule, shows the home will meet 125 or 110 litres before anything is bought. At completion the notice to Building Control must match what was actually fitted, so if any fitting has changed the calculation is updated as built.

What if fittings change on site?

The calculation needs updating with the fittings actually installed, because the notice to Building Control must reflect the finished home. A like-for-like swap, such as a shower with the same flow rate, makes no difference, but a higher-flow shower or a bigger bath can push the total over the limit. Send us the new product details before you order, so we can check them first.

Request Your Free Water Efficiency Calculation Quote

Complete the form below with the project address, number of dwellings and current project stage. Upload the latest floor plans, sanitaryware schedule, product data and planning decision notice so our team can review the requirement and coordinate an appropriate quotation.

Get Your Free Quote Today

Complete the form below and we'll provide a free, no-obligation quotation for your project.

Additional Services for Your Project (Optional)

Need more than one service? Select any additional services below and we'll include them in your quotation.





Not sure what else your project needs?Answer three questions and get the full checklist, then one quote for the lot.
Try the services finder
Call usGet a free quote