Extract Ventilation Testing

Part F Airflow Testing and Commissioning

Extract Ventilation Testing

Ventilation airflow testing for new-build homes and residential conversions, helping confirm that extract systems have been installed, configured and commissioned correctly.

Part F Testing Airflow validation for new dwellings
Calibrated Equipment Testing with suitable calibrated instruments
System Commissioning Confirming extract rates and setup
Nationwide Coverage New builds and residential conversions

Ventilation Testing for New Dwellings

New-build residential developments and conversion projects that create new dwellings commonly require ventilation testing before completion. The purpose of the test is to confirm that the installed system delivers the intended airflow and has been configured correctly.

Ventilation systems can range from simple background ventilators and intermittent extract fans through to whole-house mechanical extract and heat-recovery systems. The testing method depends on the system installed and the rooms served.

One Stop Consult coordinates extract ventilation testing through experienced technicians using suitable calibrated equipment. The results can support project completion and the information required by the relevant Building Control body.

Building Regulations

Why Is Extract Ventilation Testing Required?

Testing confirms that the installed ventilation system performs as intended rather than relying solely on product specifications.

01

Airflow Validation

The measured extract rate confirms whether the fan or whole-house system is moving the required amount of air.

02

Correct Configuration

Testing can identify systems that have been left on the wrong setting or have not been balanced correctly.

03

Moisture Control

Adequate extraction helps remove moisture generated in kitchens, bathrooms and utility rooms.

04

Project Completion

Ventilation test information may be required as part of the completion package for Building Control.

Ventilation Systems

Systems That May Require Testing

The existing OSC service covers five common ventilation system types, ranging from intermittent fans to whole-house mechanical systems.

Background Ventilation

Trickle ventilators and other background openings provide continuous low-level ventilation alongside extract provision.

Intermittent Extract Fans

Individual fans operate when required in wet rooms such as kitchens, bathrooms and utility rooms.

Continuous Mechanical Extract

A whole-house system extracts continuously from wet rooms and may operate at different normal and boost rates.

Mechanical Ventilation With Heat Recovery

MVHR systems extract stale air and supply fresh air while recovering heat through a central unit.

Centralised Systems

Multi-room or multi-unit arrangements may require balancing and commissioning across several terminals.

Mixed Ventilation Strategies

Some projects use a combination of background, intermittent and continuous ventilation measures.

Typical Extract Rates Referenced on the Existing OSC Page

The original One Stop Consult service page lists the following airflow benchmarks for common wet-room extract arrangements. The applicable requirement should always be confirmed against the project specification and the relevant version of Approved Document F.

The overall dwelling ventilation requirement also depends on the size and number of bedrooms within the property.

Kitchen intermittent fan adjacent to hob: 30 L/s
Kitchen intermittent fan away from hob: 60 L/s
Kitchen continuous extract: 13 L/s
Bathroom intermittent extract: 15 L/s
Bathroom continuous extract: 8 L/s
Utility-room intermittent extract: 30 L/s
Utility-room continuous extract: 8 L/s
Whole-dwelling rate varies with bedroom count

Whole-Dwelling Ventilation Rates

In addition to room-by-room extract rates, the dwelling must achieve an adequate overall ventilation rate. The original OSC page notes that this increases with the number of bedrooms.

As examples from the existing service information, a one-bedroom property is referenced at 13 litres per second, while a five-bedroom property is referenced at 29 litres per second. The correct target for each scheme should be confirmed from the design and current compliance documentation.

How Extract Ventilation Testing Works

The technician measures airflow at the relevant terminals and checks the system settings against the required design performance.

Review the installed ventilation system and room terminals.
Confirm normal, boost or intermittent operating modes.
Measure airflow using suitable calibrated equipment.
Compare measured results with the required extract rates.
Adjust or balance the system where this forms part of the service.
Record the final commissioning and test information.
1

System Review

Confirm the ventilation type, fan locations and required design rates.

2

Operational Check

Check that fans and controls are functioning and accessible.

3

Airflow Measurement

Measure extract performance at each required terminal.

4

Balancing or Adjustment

Where applicable, adjust system settings to improve performance and balance.

5

Final Documentation

Record the measured results for the project completion package.

Preparing for the Ventilation Test

The system should be fully installed, powered and operational before the technician attends. Incomplete grilles, ductwork, controls or electrical connections can prevent meaningful testing.

Good access to all relevant rooms and terminals will help the appointment proceed efficiently.

All fans installed and operational
Ductwork complete and connected
Grilles and valves fitted
Controls and boost switches working
Electrical power available
Access to all wet rooms provided
Design rates or schedule available
MVHR filters and terminals accessible
Common Problems

Why Ventilation Systems Fail Testing

Low airflow is often caused by installation, commissioning or ductwork issues rather than the fan unit alone.

Incorrect Fan Setting

The unit may have been left on a low commissioning setting or may not be entering boost mode correctly.

Restricted Ductwork

Long, crushed, undersized or excessively flexible duct runs can significantly reduce airflow.

Too Many Bends

Sharp bends and poor routing increase resistance and reduce the volume of air delivered.

Unbalanced Terminals

One outlet may receive too much airflow while other rooms remain below their required rate.

Blocked or Closed Valves

Terminals, grilles, dampers or filters may be restricted, incorrectly adjusted or obstructed.

Missing Background Ventilation

Extract performance and overall ventilation can be affected where the intended air inlets have not been installed or opened.

What Happens If the System Does Not Achieve the Required Airflow?

The cause should be investigated before the system is retested. Straightforward issues may include incorrect settings, closed valves or incomplete controls. More significant failures may require changes to the ductwork, fan specification or system layout.

Early commissioning is beneficial because access to ductwork and controls may become difficult once final finishes and boxing are complete.

Project Types

Extract Ventilation Testing for Residential Projects

Information Required for a Quotation

Provide the full project address, number and type of dwellings, installed ventilation system and preferred test date.

For larger developments, please also provide floor plans, the ventilation design or commissioning schedule, system manufacturer and confirmation of which plots require testing.

Nationwide Extract Ventilation Testing Service

One Stop Consult coordinates ventilation airflow testing for residential projects throughout mainland UK. Support is available for individual dwellings, conversion schemes, apartment developments and larger multi-plot sites.

Related Compliance Services

Other Services Your Project May Require

Important Ventilation Testing Information

The applicable airflow requirements depend on the project, ventilation system, design specification and relevant version of Approved Document F. The system must be fully installed, powered and accessible on the agreed test date. Incomplete ductwork, controls, grilles or electrical connections may prevent testing or affect the result. Additional charges may apply for aborted visits, adjustment work or retesting. One Stop Consult provides consultancy and coordination support through its specialist testing network.

Frequently Asked Questions

Extract Ventilation Testing FAQs

Which projects require ventilation testing?

New residential buildings and conversion projects forming new dwellings commonly require airflow testing and commissioning.

What does the test measure?

It measures the airflow delivered or extracted at relevant ventilation terminals and compares this with the required design performance.

What equipment is used?

The technician uses suitable calibrated airflow-measurement equipment appropriate to the installed terminal and system.

Do intermittent fans need testing?

Intermittent kitchen, bathroom and utility-room extract fans can require airflow validation as part of the completion process.

Can you test MVHR and whole-house systems?

Yes. Whole-house mechanical extract and heat-recovery systems can require commissioning, balancing and recorded airflow results.

Why might a fan fail the airflow test?

Common causes include incorrect settings, restrictive ductwork, sharp bends, blocked terminals, poor balancing or an undersized system.

When should testing be completed?

Testing should take place once the system is complete and operational, with enough time remaining for adjustments or remedial work before handover.

What information is needed for a quote?

Provide the project address, number of dwellings, system type, plans or ventilation design where available, and preferred date.

Do you provide ventilation testing nationwide?

Yes. We coordinate suitable technicians for eligible projects throughout mainland UK.

Request Your Free Extract Ventilation Testing Quote

Complete the form below with the project address, number of dwellings, ventilation system type and preferred test date. Upload the latest plans, ventilation design or fan schedule so our team can review the requirement and coordinate an appropriate quotation.

Get Your Free Quote Today

Complete the form below and we'll provide a free, no-obligation quotation for your project.

Additional Services for Your Project (Optional)

Need more than one service? Select any additional services below and we'll include them in your quotation.