Ventilation Testing Cost: How Much Is a Part F Test?
Ventilation testing: From £45 + VAT (per plot, on the same visit as other testing). Guide price. Get a free quote for your project. This guide explains who needs a test, what can add to the cost and how to pass first time.
In this guide
Who needs a ventilation test?
New homes
Yes. When building work creates a new home, the air flow of every extract fan must be measured and the results given to Building Control.
Conversions that create homes
Yes. A house split into flats, or an office or barn turned into homes, is treated the same way.
Extensions and refits
Not the same test. New fans in an existing home must still be commissioned so they work as intended, and Building Control can ask for the paperwork.
Cooker hoods
Yes, if the hood is part of the ventilation for the home. Only its highest setting is recorded.
Whole-house systems
Yes. Continuous extract and heat recovery (MVHR) systems are measured at each room terminal, at the everyday rate and the boost rate.
For the rates each room has to reach, see our Ventilation Testing page.
What can add to the cost?
The test itself is quick. These are the things that push the bill up:
- A visit for the fans alone. The guide price is for testing done on the same visit as other testing. A separate trip to site is priced by quote.
- A system that is not ready. If fans have no power, grilles are missing or ducts are not connected, the test cannot be done and the visit may be charged.
- A retest. If a fan falls short, the cause has to be put right and the fan measured again.
- Whole-house systems. Continuous extract and heat recovery systems have more terminals to measure and may need balancing, so they take longer than a few single fans.
- Plots tested on different days. Each extra visit adds to the cost. Testing more plots in one visit keeps it down.
How to keep the cost down
- Book it with the air test. Both are done at the end of the build, so one visit can cover both. See how much an air test costs.
- Add the sound test if you need one. Attached homes and flats usually need sound insulation testing as well, and it can be planned for the same visit.
- Have the plots ready together. Tell us how many homes will be finished on the day, so they can be tested in one go.
- Send the design first. The fan schedule and design rates tell the technician what each fan has to reach before they arrive.
How to pass first time
Most fails come from the ducting and the settings, not the fan. Before the visit:
- Check every fan has power and is set to the right speed for its room.
- Keep ducts short and straight, with as few bends as you can.
- Pull flexible duct tight, and make sure it is not crushed.
- Check the outside grille is clear and any shutter moves freely.
- Fit the trickle vents and leave them open.
- Check boost switches and controls work.
- Leave clear access to every kitchen, bathroom, utility room and toilet.
What do I get for the money?
Each fan is measured with a calibrated air flow meter and hood. The results are written on a commissioning sheet, often called a ventilation test certificate, with the air flow at each fan in litres a second. This is the record Building Control asks for at completion.
The law sets a deadline for the paperwork. For a new home, Building Control must be given the results no later than five days after the final test. That is the legal deadline in Regulation 42, not the time it takes to arrange a test.
When should I book?
Book once the ventilation is fully fitted, wired and running, and while there is still time before handover to put right anything that falls short. Early is better, because ducts and controls are harder to reach once boxing and finishes are complete.
Frequently asked questions
How much does Ventilation Testing cost?
Ventilation testing is From £45 + VAT (per plot, on the same visit as other testing). Guide price. Get a free quote for your project.
Can I book a ventilation test on its own?
Yes. A visit for the fans alone is priced by quote, because the guide price is for testing done on the same visit as other testing. Send us the address and the number of fans and we will price it.
Is Ventilation Testing a legal requirement?
For a new home, yes. Regulation 42 of the Building Regulations says the air flow of mechanical ventilation must be tested when building work creates a new dwelling, and the results given to Building Control.
Do I need a test for an extension or a new bathroom?
Not the new-home test. A new fan in an existing home must still be commissioned so it works as intended, and Building Control can ask for a commissioning notice. Ask your Building Control body what it wants to see.
Can my electrician test the fans instead?
Yes, if it is done the way Approved Document F sets out. Each fan must be measured with a hooded air flow meter that is accurate to 5% and was calibrated in the last 12 months at a UKAS-accredited centre, and the results recorded on a commissioning sheet. A note that the fans were fitted and switched on is not enough. Building Control decides whether to accept it.
What happens if a fan fails?
The cause is found and put right, then the fan is measured again. Simple causes are a wrong speed setting or a closed valve. Harder ones are long, crushed or badly routed ducts, which may need changing.
Can it be done on the same day as the air test?
Yes, in most cases. Both tests are done when the home is finished, so they are often booked together, and that is what the guide price is based on.
What do you need to give me a price?
The site address, the number and type of homes, the ventilation system fitted and the date you would like. Floor plans and the fan schedule help if you have them.