Cavity Barriers and the Building Regulations
Cavity barriers stop fire and smoke travelling unseen through the hidden spaces in a building: wall cavities, ceiling and floor voids and roof spaces. Approved Document B says where they go, how well they must resist fire and how they should be fixed. This guide sets out those rules for houses, flats and other buildings, explains how cavity barriers differ from fire-stopping and cavity closers, and lists what gets checked on site.
The rules below are for England and come from Approved Document B (fire safety), 2019 edition incorporating the 2020, 2022, 2025 and 2026 amendments, published on GOV.UK in September 2026. Volume 1 covers homes and Volume 2 covers buildings other than homes. The cavity barrier rules are much the same in both.
What is a cavity barrier?
For fire safety, a cavity is any concealed space. Approved Document B says cavities give a ready route for smoke and flame, and that this is more dangerous because any spread is hidden. A cavity barrier is a construction inside a cavity that closes it, so smoke and flame cannot get in, or divides it, so they cannot travel along it.
Cavity barriers do two jobs: they close the edges of cavities and they split large cavities into smaller ones.
Cavity barrier, fire-stopping or cavity closer?
These three are often mixed up, and Approved Document B warns not to confuse cavity barriers with fire-stopping.
Cavity barrier
A barrier inside a concealed space that closes or divides it. It must give at least 30 minutes integrity and 15 minutes insulation.
Fire-stopping
A seal that fills a gap, joint or service opening through a fire-resisting wall or floor, so the wall or floor keeps its full fire resistance.
Cavity closer
The material that closes a masonry cavity at the top of a wall and around windows and doors. Where the wall meets the masonry exemption described below, the closer does not need any particular fire performance.
Where cavity barriers are needed
Approved Document B lists the places where cavity barriers should be fitted:
Edges of cavities
Around the edges of every cavity, including around openings such as windows, doors and points where services go in and out.
External cavity walls
Where an external cavity wall meets every compartment floor and compartment wall, such as the wall between two semi-detached houses or between two flats.
Internal cavity walls
Where an internal cavity wall meets every compartment floor, compartment wall or other fire-resisting wall or door assembly.
Above escape routes
Where the fire-resisting walls of a protected escape route stop short of the floor or roof above, the void above or below needs cavity barriers on the line of the wall, or a fire-resisting ceiling (at least EI 30) right across the building or compartment.
Above a protected stair in a house
A house with a storey more than 4.5 metres above ground needs cavity barriers or a fire-resisting ceiling (at least EI 30) above the protected stairway enclosure. This often comes up on loft conversions.
Large cavities in other buildings
In buildings other than homes, cavities and roof spaces must be divided so no undivided cavity is bigger than the limits in the table further down.
One rule catches people out. A compartment wall must be built right up to the underside of the floor or roof above. Approved Document B says it is not acceptable to stop the wall at ceiling level and fit cavity barriers in the roof space above it instead.
When a masonry cavity wall does not need cavity barriers
An ordinary masonry cavity wall can be left out of the cavity barrier rules if it matches the diagram in Approved Document B (Diagram 5.3 in Volume 1, 8.2 for flats and 9.2 in Volume 2):
Two solid leaves
Both leaves are brick or concrete, each at least 75mm thick.
Closed at the top and around openings
The cavity is closed at the top of the wall, unless it is totally filled with insulation, and around every opening. The materials used to close it do not need a set fire performance.
Meter cupboards
No more than two per home, each opening in the outer leaf no bigger than 800 by 500mm, and the inner leaf only pierced by a sleeve no bigger than 80 by 80mm that is fire-stopped.
Timber frame, steel frame and rainscreen walls do not fall under this exemption, so they need cavity barriers at the places listed above. Taller blocks of flats also have their own rules on external walls; see our external wall surveys page.
Maximum cavity sizes in buildings other than homes
Volume 2 sets the largest undivided cavity allowed in buildings other than homes (purpose groups 2 to 7). The size is measured in any direction.
| Where the cavity is | Surface exposed in the cavity | Largest size in any direction |
|---|---|---|
| Between a roof and a ceiling | Any | 20 metres |
| Any other cavity | Class C-s3, d2 or better | 20 metres |
| Any other cavity | Worse than class C-s3, d2 | 10 metres |
The limits do not apply to some cavities, including a cavity in a wall that is fire-resisting only because it is loadbearing, a masonry wall that meets the exemption above, a floor or roof void above a fire-resisting ceiling that runs through the building or compartment up to 30 metres, and a cavity under a ground floor that is less than 1,000mm high or not normally accessible. Where a single room’s ceiling or floor void is bigger than the table allows, cavity barriers can go on the line of the room’s walls, at most 40 metres apart, if the exposed surface is class C-s3, d2 or better. Bigger voids still are possible, but only with a long list of conditions, including a fire alarm to BS 5839-1 and non-combustible supports and fixings.
How good a cavity barrier has to be
A cavity barrier, tested from each side separately, should give at least 30 minutes integrity (E 30) and 15 minutes insulation (I 15). Part of the building built for another purpose can count as the cavity barrier if it reaches the same standard.
In a stud wall or partition, or around openings, cavity barriers may be made of:
Steel
At least 0.5mm thick.
Timber
At least 38mm thick.
Mineral wool
Polythene-sleeved mineral wool, or mineral wool slab, squeezed tight into the cavity.
Boards
Calcium silicate, cement-based or gypsum-based boards at least 12mm thick.
Approved Document B notes that these materials do not necessarily reach E 30 and I 15 on their own. Around a window or door, the frame itself can act as the cavity barrier if it is steel or timber of at least those thicknesses.
Fixing cavity barriers properly
A cavity barrier only works if it stays in place in a fire. Approved Document B says it should be:
Tight and fixed
Tightly fitted to a rigid construction and mechanically fixed. Where that is not possible, for example against slates, tiles or profiled sheeting, the junction should be fire-stopped.
Allowing for movement
Fixed so that settlement, shrinkage, temperature changes and wind movement of the outer wall will not open gaps.
Not pulled down by services
Fixed so that pipes, cables or their supports collapsing or melting in a fire will not make it fail.
On a sound backing
Fixed to something that will last. A suspended ceiling that runs over a fire-resisting wall and is not itself rated at least EI 30 can collapse and take the cavity barrier with it.
Openings through a cavity barrier
Openings through a cavity barrier should be limited to:
Doors
Fire doorsets rated at least E 30.
Pipes
Pipes that follow the fire-stopping rules for pipes in Approved Document B.
Cables
Cables, or conduits holding one or more cables.
Ducts and dampers
Openings with a suitable fire damper, and ducts that are fire-resisting (at least E 30) or have a fire damper where they pass through.
Send us the drawings and tell us what the building is and how tall it is. We can arrange an independent inspection of cavity barriers and fire-stopping, or an external wall survey for a block of flats, with a clear written report of what needs putting right.
What gets checked on site
Cavity barriers are hidden once the building is finished, so they need checking while the cavities are still open. Based on the rules above, an inspector will look at:
Position
Barriers at every edge, opening and compartment line shown on the drawings, with no runs left out.
Fit
No gaps at joints, corners or where the barrier meets the frame, sheathing or roof covering.
Fixing
Mechanical fixings, and mineral wool barriers squeezed into the cavity rather than loose.
Product
The product and size match the specification, and are installed the way the maker’s test evidence shows.
Services
Anything passing through is one of the allowed openings and is sealed.
Photographs taken before the cavities are closed are the best record. On new buildings and some building work, the fire safety information handed to the owner under regulation 38 should include the cavity barriers, so a good set of photos and drawings helps there too.
Replacement windows and existing buildings
Approved Document B says that when windows are replaced, cavity barriers may be needed around the new opening. On older buildings, missing or damaged cavity barriers are often found during refurbishment or a fire risk assessment. For blocks of flats, the external wall survey or FRAEW looks at cavity barriers where they can be safely seen.
Changes coming in 2029
The 2029 amendments to Approved Document B take effect on 2 September 2029. They remove the old national fire resistance classes, leaving the European classes. The cavity barrier standard is already written in European terms (E 30 and I 15). Work with a building notice, initial notice or full plans application made before that date can follow the current edition, as long as the work has started and is sufficiently progressed before that date, or within six months after it.
Frequently asked questions
Where are cavity barriers required?
At the edges of cavities including around windows, doors and service openings, where an external or internal cavity wall meets a compartment floor or wall, above fire-resisting walls that stop short of the floor or roof above, and in buildings other than homes, at intervals to divide large cavities.
What is the difference between a cavity barrier and fire-stopping?
A cavity barrier closes or divides a hidden space. Fire-stopping seals gaps and service openings through a fire-resisting wall or floor so it keeps its fire resistance. Approved Document B treats them separately.
What is the difference between a cavity barrier and a cavity closer?
A cavity closer closes a masonry cavity at the top of a wall and around openings. Where the wall meets the masonry exemption, the closer needs no set fire rating. A cavity barrier must give at least 30 minutes integrity and 15 minutes insulation.
How long does a cavity barrier need to resist fire?
At least 30 minutes integrity (E 30) and 15 minutes insulation (I 15), tested from each side separately.
Do houses need cavity barriers?
Yes. Houses need them at the edges of cavities and around openings, and where a cavity wall meets a compartment wall such as the wall to the house next door. A masonry cavity wall that meets the exemption in Approved Document B does not need them.
Can timber be used as a cavity barrier?
Yes. In a stud wall or partition, or around openings, timber at least 38mm thick can be used. Approved Document B notes this does not necessarily reach E 30 and I 15 on its own.
What is the maximum distance between cavity barriers?
In buildings other than homes, an undivided cavity should be no more than 20 metres in any direction, or 10 metres where the exposed surface is worse than class C-s3, d2. Some cavities are exempt.
Can pipes and cables pass through a cavity barrier?
Yes. Pipes that follow the fire-stopping rules, cables and conduits are allowed. Ducts must be fire-resisting or have a fire damper, and doors must be fire doorsets rated at least E 30.
Get a Free Quote for Your Project
Send us the drawings and tell us what the building is and how tall it is. We can arrange an independent inspection of cavity barriers and fire-stopping, or an external wall survey for a block of flats, with a clear written report of what needs putting right.
Last reviewed: November 2026. Checked against Approved Document B (fire safety) Volumes 1 and 2, 2019 edition incorporating the 2020, 2022, 2025 and 2026 amendments, published on GOV.UK. General guidance for England only. Get project-specific advice before relying on it.