Sound Insulation Testing
Delivered 55+ times since 2018
A sound insulation test measures how much noise passes through the walls and floors between homes. Part E normally needs one before completion on new houses and flats that share a wall or floor, and on buildings converted into homes. From £375 + VAT. Guide price. Get a free quote for your project.
Sound Insulation Testing for Residential Projects
Sound insulation testing measures how effectively separating walls and floors reduce the transfer of noise between adjoining dwellings or rooms for residential purposes. The testing is commonly completed near the end of construction as part of the Building Regulations compliance process.
The assessment normally includes airborne sound testing across separating walls and floors, together with impact sound testing where one dwelling is located above another. The results identify whether the completed construction achieves the required acoustic performance.
One Stop Consult coordinates suitably experienced acoustic testers for individual homes, apartment developments, houses converted into flats, student accommodation and other eligible residential schemes throughout mainland UK.
Why Is Sound Insulation Testing Required?
Separating construction must provide suitable resistance to noise transfer between neighbouring residential spaces.
Part E Compliance
Testing can demonstrate that completed separating walls and floors achieve the acoustic performance required for the project.
Pre-Completion Evidence
The test is normally completed before occupation so the results can form part of the Building Control completion information.
Occupant Comfort
Effective separating construction helps reduce disturbance from speech, televisions, music, footsteps and everyday activity.
Construction Verification
Testing confirms the actual installed performance rather than relying only on drawings, product data or predicted values.
Airborne and Impact Sound Testing
The required testing depends on the arrangement of the dwellings and whether the separating element is a wall or a floor.
Airborne Wall Testing
A controlled sound source is generated in one room and measured in the adjoining room to assess transmission through a separating wall.
Airborne Floor Testing
Airborne noise transmission is measured between vertically adjoining dwellings where a separating floor forms the boundary.
Impact Floor Testing
A standard tapping machine is used on the upper floor while sound levels are measured in the room below.
Background Noise Measurement
Background levels are recorded so the tester can account for other noise affecting the receiving room.
What Figures Do You Need to Pass?
Approved Document E sets the minimum standards for walls and floors between homes in England. Conversions have slightly easier targets than new homes.
| Test | New homes and flats | Conversions (change of use) |
|---|---|---|
| Airborne sound through a separating wall (DnT,w + Ctr) | 45 dB or more | 43 dB or more |
| Airborne sound through a separating floor (DnT,w + Ctr) | 45 dB or more | 43 dB or more |
| Impact sound through a separating floor, such as footsteps (L'nT,w) | 62 dB or less | 64 dB or less |
Student Rooms, Hotels and Care Homes
Hostels, hotels, halls of residence and residential homes count as rooms for residential purposes, and Approved Document E gives them their own figures. Hospital patient rooms are not included.
Purpose-built rooms: walls 43 dB or more, floors 45 dB or more, impact sound 62 dB or less.
Rooms formed by a change of use: walls and floors 43 dB or more, impact sound 64 dB or less.
For airborne tests a higher number is better. For impact tests a lower number is better. Stairs that separate homes use the floor figures.
What Is One Set of Tests?
Pre-completion sound testing is done in sets, not one test at a time. Approved Document E says what one set means for each type of building.
Houses and Bungalows
Two individual tests: two airborne tests of the separating walls.
Flats With a Separating Floor Only
Four individual tests: two airborne and two impact tests of the separating floors.
Flats With Separating Walls and Floors
Six individual tests: four airborne tests, two of walls and two of floors, plus two impact tests of floors. A full set needs access to at least three flats.
Rooms for Residential Purposes
Rooms such as student rooms and hostels are tested on the same principles, adapted to suit the building.
How Many Sets Will You Need?
Houses, flats and rooms for residential purposes are three separate groups, and each different wall or floor construction forms its own sub-group. The first homes to finish in each group or sub-group are tested, whatever the size of the site, so even a single pair of homes should be tested. After that, Approved Document E asks for at least one set of tests for every ten houses, flats or rooms in that group or sub-group.
If a set fails, the rooms are put right and tested again, and Building Control can ask for more testing until it is satisfied.
How Sound Insulation Testing Works
The acoustic technician creates controlled sound within a source room and measures the resulting level in the adjoining receiving room. Room dimensions, reverberation and background noise are also considered when calculating the final result.
Project Review
Review the dwelling arrangement and identify suitable test rooms and separating elements.
Site Readiness Check
Confirm that the building is complete, secure and quiet enough for reliable acoustic measurements.
Airborne Testing
Generate controlled sound and measure transmission across the selected wall or floor.
Impact Testing
Use a tapping machine to assess impact transmission through separating floors where required.
Final Report
Issue the results for the client, design team and Building Control body.
Preparing the Building for Sound Testing
The tested rooms should be substantially complete and in their normal finished condition. Missing doors, floor finishes, sockets, seals or service penetrations can affect the result and may prevent meaningful testing.
The site should also be reasonably quiet. Construction work, generators, loud equipment and uncontrolled access can interfere with acoustic measurements.
How Are Test Rooms Selected?
The required sample depends on the number of dwellings, the separating construction types and the layout of the development. Suitable rooms are normally selected to represent the different wall and floor constructions used across the scheme.
Bedrooms and living rooms are commonly preferred because their size, use and construction are usually more suitable for reliable testing. Kitchens, bathrooms, corridors and very small rooms may not always be appropriate.
Common Causes of Sound Test Failure
Acoustic performance can be reduced by small gaps, rigid connections and incomplete junctions that allow sound to bypass the intended separating construction.
Unsealed Service Penetrations
Gaps around pipework, cables, sockets and ducts can create direct paths for airborne sound.
Poor Perimeter Sealing
Junctions around walls, floors, ceilings and external façades must be completed in accordance with the acoustic design.
Rigid Bridging
Mechanical fixings, debris or direct connections can bridge resilient layers and increase sound transmission.
Incorrect Floor Build-Up
Missing resilient layers, poor edge isolation or unsuitable floor finishes can lead to impact sound failure.
Incomplete Cavity Construction
Missing insulation, mortar bridges or poorly formed cavities can reduce the performance of separating walls.
Flanking Transmission
Sound may travel around the separating element through floors, roofs, façades, corridors or adjoining structural components.
What Happens If a Sound Test Fails?
A set of tests fails if any single test in it falls short. Building Control will then want to see that other rooms and homes built the same way also meet the standard, and the rate of testing should go up until it is satisfied the problem is solved.
The result should be reviewed alongside the construction details and site condition to identify the likely weakness. Remedial work may involve sealing gaps, correcting floor-edge details, improving linings, removing rigid bridges or addressing flanking paths.
Once the remedial work has been completed, the affected separating element can be retested. It is sensible to allow time for this before the planned completion or occupation date.
Pre-Completion Testing and Robust Details
Some new-build dwelling schemes may use an eligible registered Robust Detail instead of pre-completion testing, provided the construction, registration and inspection requirements are followed correctly.
New-Build Projects
Suitable new-build schemes may have the option to use registered Robust Details for eligible separating constructions.
Conversions
Residential conversions generally rely on pre-completion testing rather than the Robust Details route.
Design Changes
Deviations from a registered construction can affect eligibility and may result in a requirement for testing.
Confirm the Route Early
The intended compliance route should be agreed with the project team and Building Control before construction progresses.
Who Can Carry Out a Sound Test?
Approved Document E says the person carrying out the work should arrange testing by a test body with suitable third-party accreditation.
UKAS Accreditation
Test bodies should preferably have UKAS accreditation, or a European equivalent, for field measurements.
ANC Registration
Members of the Association of Noise Consultants Registration Scheme are also regarded as suitably qualified to carry out pre-completion testing.
What the Report Must Show
The address, property type, test dates, the test body and its accreditation number, the rooms used, each result, the figure needed, and a Pass or Fail for each test.
Sound Insulation Testing for Residential Developments
Information Required for a Quotation
Provide the full project address, number and type of dwellings, description of the development and preferred test date.
Please also provide the latest floor plans and details of each separating wall and floor construction. For larger schemes, identify any different construction types used across the development.
Nationwide Sound Insulation Testing Service
One Stop Consult coordinates airborne and impact sound insulation testing for residential projects throughout mainland UK. Support is available for individual dwellings, conversions, apartment developments and larger multi-unit schemes.
Other Services Your Project May Require
Important Sound Insulation Testing Information
The required test sample and performance criteria depend on the project type, separating constructions, applicable Building Regulations route and Building Control requirements. The tested rooms must be sufficiently complete and suitable for reliable measurements. Excessive site noise, incomplete finishes or unavailable access may prevent testing or affect the result. Additional charges may apply for aborted visits, investigation or retesting. One Stop Consult provides consultancy and coordination support through its specialist acoustic testing network.
Sound Insulation Testing FAQs
What is sound insulation testing?
It measures how effectively separating walls and floors reduce airborne and impact sound transmission between adjoining residential spaces.
What is airborne sound testing?
Controlled noise is generated in one room and measured in the adjoining room to assess transmission through a separating wall or floor.
What is impact sound testing?
A standard tapping machine operates on the upper floor while the resulting sound is measured in the room below.
When should the test be completed?
Testing should take place once the relevant rooms and separating constructions are complete but before final handover or occupation.
Is a sound test needed for conversions?
Yes. Pre-completion testing applies to houses and flats formed by a material change of use, such as a barn or office converted to homes, and to rooms for residential purposes made by a conversion. Robust Details cannot be used instead. Conversions have their own pass figures: at least 43 dB for airborne sound and no more than 64 dB for impact sound.
What happens if a test fails?
The construction should be investigated, suitable remedial work completed and the affected separating element retested.
Does every dwelling need to be tested?
No. Testing is done on a sample: a set on the first homes to finish in each group of the same construction, then at least one set for every ten homes in that group. Building Control can ask for more if a test fails.
What information is needed for a quotation?
Provide the address, number of dwellings, plans, separating wall and floor details, project type and preferred test date.
Do you provide Sound Insulation Testing nationwide?
Yes. We coordinate suitable acoustic testers for eligible projects throughout mainland UK.
What is the pass mark for a sound test?
For new homes, walls and floors need at least 45 dB for airborne sound, and floors no more than 62 dB for impact sound. Conversions need 43 dB and 64 dB.
How many sets of sound tests do I need?
At least one set for every ten houses, flats or rooms of the same construction, after a first set on the earliest homes to finish in each group. A set for houses is two airborne wall tests. For flats it is four tests where there are separating floors only, or six where there are separating walls and floors.
How much does Sound Insulation Testing cost?
From £375 + VAT. Guide price. Get a free quote for your project. Our Sound Testing cost guide explains what changes the price.
Who can carry out a sound test?
Approved Document E says a test body should preferably have UKAS accreditation for field measurements. Members of the ANC Registration Scheme are also regarded as suitably qualified.
If one test fails, does the whole set fail?
Yes. A set of tests fails if any single test in it falls short. The rooms that failed need remedial work, and Building Control will usually want further testing.
Do student rooms and hotels need sound testing?
Yes, normally. Hostels, hotels, halls of residence and residential homes are covered by Part E as rooms for residential purposes, with their own pass figures. Tests are between the main rooms, adapted to suit the building.
What is a noise transfer assessment?
It usually means checking how much sound passes through a wall or floor between two spaces. Between homes, that is what a Part E sound insulation test measures. If the noise comes from outside or a business nearby, you may need a noise survey as well.
When must sound test results go to Building Control?
In England, regulation 41 of the Building Regulations says the person carrying out the work must give Building Control a copy of the results no later than the date the completion notice is due, which is within five days of the work finishing. On higher-risk buildings they go to the Building Safety Regulator with the completion certificate application.
Do I need Sound Testing for a house extension?
Not usually. Part E sound testing is for walls and floors that separate homes, or rooms for residential purposes, in new buildings and in buildings converted into homes. An extension to a single house does not create a separating wall, so testing is not normally needed. If your work turns a house into flats, testing will usually be needed.
Who is responsible for soundproofing between flats?
For new flats and flats made by a conversion or change of use, the person carrying out the building work, usually the developer or builder, must meet Part E of the Building Regulations. That means walls and floors between flats must reach the required sound insulation, shown by pre-completion sound tests or by building to Robust Details. Building Control will not sign the work off until the results are in. Part E does not apply after the event to older flats that were built or converted before the rules, so in an existing block it is usually a matter between the owners, the freeholder and the lease. Our guide What is Sound Insulation Testing? explains the tests.
Do you need Building Regulations approval for soundproofing?
Not usually, if you are simply adding soundproofing to a home you already live in, such as an extra layer on a party wall. Part E applies when homes are built or created: new houses and flats, and buildings converted into homes. There the walls and floors between homes must reach set sound figures, usually proved by a test before completion. If you are converting a house into flats, speak to Building Control before work starts.
Can I avoid testing with Robust Details?
Only for new-build houses and new buildings containing flats, and only for separating walls and floors built to a registered Robust Detail. The builder must tell Building Control before work starts, giving the unique number issued by Robust Details Limited for each home. Robust Details cannot be used for conversions or for rooms for residential purposes, so those must be tested.
What do the Building Regulations say about sound insulation testing?
Part E of the Building Regulations says homes must resist the passage of sound from adjoining homes and from other parts of the same building. Regulation 41 then requires sound insulation testing on new homes and conversions with separating walls or floors, carried out in line with Approved Document E, with the results given to Building Control. New homes built to a registered Robust Detail do not need the test.
Request Your Free Sound Insulation Testing Quote
Complete the form below with the project address, number of dwellings, development type and preferred test date. Upload the latest floor plans and separating wall and floor details so our team can review the requirement and coordinate an appropriate quotation.
Our work
Sound Insulation Testing projects we've delivered
Often booked together
Bundle Sound Insulation Testing with
One quote, one point of contact and a bundle discount when you book more than one service.
Air Tightness Testing
Air tests with certificates for Building Control and SAP.
View service Part FExtract Ventilation Testing
Extract fan flow-rate testing for new builds.
View service Building RegulationsBuilding Control
Building Regulations approval, from plans to completion certificate.
View serviceNear you
Sound Insulation Testing by area
We work nationwide. These are the areas we cover most often.